 |
3500 STAINLESS STEEL FILTER REGULATOR STAINLESS STEEL FILTER REGULATOR for the offshore, food, pharmaceutical and allied industries.
Ambient temperature
-20ºC to +80ºC (-4ºF to +176ºF)
Low temperature version
-50ºC ( -58ºF)
Manual drain - 20 bar (290 psi)
Automatic drain - 17 bar (247 psi)
3/4", 1", NPT(BSP option available) -> More Details |
|
 |
2712 MODULATING CONTROL VALVE
DN4 – DN100
CV0.5 – CV140
Max temp 180
4-20mA, 0-10vdc, PT100 or Pulse input
Low Cost with High Performance -> More Details |
|
 |
T6100 FAIL FREEZE I-P TRANSDUCER is an accurate, robust, refined flapper–nozzle controlled transducer.
Locks in “Last Position”
Accurately captures setpoint
IP65 Rating
Moisture resistant PCB -> More Details |
|
 |
SIEMENS SITRANS LR250 RADAR LEVEL TRANSMITTER
Is a 2-wire, 25 GHz pulse radar level transmitter
for continuous monitoring of liquids and slurries in storage and
process vessels including high temperature and pressure, to a
range of 20 m (66 ft). -> More Details |
|
 |
24xfs LOW PRESSURE GAS MOTORIZED REGULATOR engineered for ultra high sensitivity at very low outlet pressures
High Accuracy
No Bleed
Low pressure control
High Flow Lock in last position -> More Details |
|
 |
FC300 COMPACT CORIOLIS MASS FLOW METER
Compact sensor design only 135x205x58 mm
Accuracy ±0.1% of mass flow rate
Large turndown range 1:100
Corrosion and resistant enclosure in stainless steel -> More Details |
|
 |
SIEMENS SITRANS DS III PRECISION DIGITAL TRANSMITTER
The SITRANS P Series DSIII is a precision digital transmitter for pressure, absolute pressure, differential pressure, flow and level and has extensive diagnostics and simulation functions.
100/1 turndown
Accuracy 0.1%
Max pressure 400 BAR
PRESSURE AND DIFFERENTIAL PRESSURE MEASUREMENT -> More Details |
|
 |
DM600 BATTERY POWERED INDICATOR
BATTERY POWERED
RTD OR TC INPUT OPTIONS
PUSH BUTTON CONFIGURABLE
4 DIGIT DISPLAY
HOUSING ABS PLASTIC OR STAINLESS STEEL
SEALED TO IP67
10 YEAR WARRANTY
ATEX APPROVED IN ABS HOUSING -> More Details |
|
 |
FUS 1010 SITRANS F US clamp-on ultrasonic flow meters measure the flow of electrically conductive and non-conductive liquids as well as gas.
Pipe size - 6.4 mm ... 9.14 m
Accuracy ± 0.5% ... 1.0% of flow,
Batch repeatability ± 0.15% of flow,
Liquid temperature
Standard -40 ... +120 °C (-40 ... +250 °F)
Optional -40 ... +230 °C (-40 ... +450 °F) -> More Details |
|
 |
Mass 6000i/EExd The MASS 6000 Ex d transmitter is manufactured in stainless steel (AISI 316L) and
able to with stand harsh installation conditions in hazardous applications within the
process and chemical industry. -> More Details |
|