Approvals DVGW approved Up to size 11/4" approved for low noise Group 1. Media Water compressed air & Nitrogen. Body material stainless steel. Spring bonnet material synthetic material. Port connection type external threads. Integral filter 0,16mm
Media Water, compressed air & nitrogen. Body material red bronze RG5. Spring bonnet material metal. Port connection type flanges. Max. media temperature 70oC. Static pressure PN25. Integral filter 0,5mm. Pressure setpoint range 0,5 - 2 bar
Pressure, overpressure, grey painted aluminium housing G1/2 male, 1/2 NPT male, 1/4 NPT female ,1/2 NPT female Process temp -40 ... +150 °C SPDT Microswitch.
The MCX capsule gauge is designed for low and negative pressure measurements and is particularly convenient for measuring pressure on ...
The MEP5-MMN5 gauges have been specifically designed to fulfill the requirements of aggressive environments and fluids. External parts, sensing element ...
The MEX2-MEX3-MEM2-MEM3 pressure gauges are intended for process industries such as chemical, petro-chemical, energy or gas industries and ...
The MEX5-MEM5 pressure gauges are intended for process industries such as chemical, petro-chemical, energy or gas industries and have been designed to satisfy requirements to operate in aggressive environments.
These gauges have been designed to fulfill requirements of the process industries (petrochemical, biochemical and power).
The pressure gauges of the MTA5 and MTX5 series are well suited for low pressure measurements both with sensing elements made of 2 stainless steel laser-welded diaphragms.
Measurement of differential pressures from 0...0.1 bar with static pressures from 0.6 to 100 bar. MX-MT: 90° radial connections or connections on the back.
Measuring range is 0-29 psi/0-729 psi. Accuracy is
THIS PRODUCT HAS BEEN REPLACED BY TYPE 8316 Ceramic measurement cell. Two-wire version. Compact, stable construction for the highest operational reliability. Media stop system if bursting pressure exceeded.
The compact Type 8316 pressure transmitter meets the highest requirements with regard to mechanical loading, EMC characteristics and operational reliability and is particularly suitable for demanding industrial applications. This product replaces Burkert Type 8314.
Continuous 2point 3point & On/Off control. Ratio control function. Sensor inputs (4-20 mA, 0-10 V, frequency, RDT). Control of proportional process & motor valves. Burkert proportional valves and flow meters are memorized. 1/16 DIN size panel version
Up to 6000 psig supply pressure. Variety of spring ranges covering 0-3000psi outlet pressure. 1/4" NPT/BSPT Ports. Inconel diaphragm suitable for liquid or gas use.
Up to 10000 psig supply pressure. Variety of spring ranges covering 0-10000PSI outlet pressure. 1/4" NPT/BSPT Ports. Suitable for liquid or gas use.
Supply pressure 500 psig Maximum/(75 psig Silicone Elastomers/250 psig Check valve) Sensitivity less than 1/8' Water Column. Adjustment range 0-2 psig to 5-400 psig. Pipe Size 1/4' NPT - 1/2' NPT/BSPT.
Flow capacity in excess of 3000 SCFM (150 psig supply 40 psig set). Maximum supply pressure 250 psig. Adjustment range 0-10 psig to 2-150 psig. Pipe size 1' NPT - 1 1/2' NPT.
Flow capacity 50 SCFM (100 psig supply 20 psig set point). Sensitivity 0.5" W.C. Supply pressure 250 psig maximum. Adjustment range 1/2-10 psig to 2-150 psig. Pipe size 1/4'NPT - 3/8' NPT/BSPT.
System Pressure 500 psig maximum. Sensitivity Less than 1/8' Water Column. Adjustment range 0-2 to 5-400. Pipe size 1/4' NPT - 1/2' NPT/BSPT.
Supply pressure 150psi max. Sensitivity 0.05' Water Column. Adjustment ranges from 0-0.5psi to 0-12 psi. Pipe Size 1/4' to 1/2' NPT/BSP.
Supply Pressure 250 psig Maximum. Sensitivity 1/2' Water Column. Pipe Size 1/4' NPT - 3/8' NPT/BSPT.
Supply Pressure 250 psig Maximum. Sensitivity 1' Water Column. Pipe Size 3/8' NPT - 3/4' NPT/BSPT.
Max Vacuum Capacity 30inHg. 1/2' water gauge control senstivity. 1/4', 3/8' and 1/2' Pipe sizes.
Control Sensitivity of 1/8' water column for precision applications. Max Vacuum capacity 30inHg. 1/4' 3/8' and 1/2' Pipe sizes.
Maximum Output Pressure 150 psig. Maximum Supply Pressure 250 psig. Flow Capacity SCFM @ 100 psig supply 45, 20 psig output. Sensitivity 1/4' Water Column. Pipe size 1/4' NPT - 3/8' NPT/BSPT.
Supply Pressure 250 psig Maximum. Output Pressure 150 psig Maximum. Flow Capacity (SCFM) 830 @100 psig, 20 set point. Sensitivity 1' Water Column. Pipe Size 1' NPT - 1 1/2' NPT.
Supply Pressure 250 psig Maximum. Output pressure 150 psig Maximum. Sensitivity 1' Water Column. Pipe size 1 1/2' NPT.
PLEASE NOTE THIS PRODUCT IS NO LONGER AVAILABLE Wide choice of input signals inputs. Option for limit switches. Locks last position. Available in 4 AC motor speeds.
PLEASE NOTE THIS PRODUCT IS NO LONGER AVAILABLE Range 0-20' Water. Power Supply 12-24 VDC. DC Pulse Input with 24VDC. IP65.
Our in house team have decades experience working on pressure control applications, and are suitably well equipped to offer you advice and guidance - not only on the products you see here, but the full scope of pressure control implementation.
We stock thousands of products, many more than we could ever list here, so if you don't find exactly what you need, contact our team here, or on +44 (0) 800 328 8511 - they'll happily advise and source it for you.