The SITRANS P Series DSIII Pressure & Differential Pressure Transmitter is a precision digital transmitter for pressure, absolute pressure, differential pressure, flow and level and has extensive diagnostics and simulation functions.
Please note this product has been replaced by the Siemens P320 & P420 product range and will not be available from the February 2020
SITRANS P DS III / P410, HART,4-20 mA Transmitter for pressure 7MF4033 - 1 Measuring cell filling silicone oil, normal cleaning D Span: 0,16 ... 16 bar g (2.32 ... 232 psi g), overload limit 32 bar A Diaphragm stainless steel, measuring cell stainless steel 0 Process connection: connection shank G1/2 B to EN 837-1 0 Die-cast aluminium housing 1 Standard design B Explosion protection EEx ia B Electric connection and cable inlet: cable gland M20 x 1.5 6 Housing cover with window Y01 Range -1 to 4 bar C11 Quality inspection certificate (Factory calibration) to IEC 60770-2 Full P/N 7MF40331DA00-1BB6.Z C11. Y01 7MF4033-1DA00-1BB6-Z C11+Y01 Y01: -1 .4 BAR
SITRANS P DS III / P410, HART,4-20 mA Transmitter for pressure 7MF4033 - 1 Measuring cell filling silicone oil, normal cleaning D Span: 0,16 ... 16 bar g (2.32 ... 232 psi g), overload limit 32 bar A Diaphragm stainless steel, measuring cell stainless steel 0 Process connection: connection shank G1/2 B to EN 837-1 0 Die-cast aluminium housing 1 Standard design B Explosion protection EEx ia B Electric connection and cable inlet: cable gland M20 x 1.5 6 Housing cover with window Y01 Range -1 to 4 bar C11 Quality inspection certificate (Factory calibration) to IEC 60770-2 Full P/N 7MF40331DA00-1BB6.Z C11. Y01 7MF4033-1DA00-1BB6-Z C11+Y01 Y01: -1 .4 BAR
The Siemens 7MF4033 1EA00+ SITRANS P DS III Pressure Transmitter is a user friendly and highly accurate digital transmitter. The 7MF4033 Pressure Transmitteris simple to use, but comes with a wide range of options. This extensive functionality allows the 7MF4033 to be precisely adapted to your requirements.
7MF4033 Pressure Transmitter Benefits
High quality and long service life
Reliability under extreme chemical and mechanical loads
Suitable for both aggressive and non-aggresive gasses, vapors and liquids
Extensive diagnosis and simulation functions
Wetted parts made from high grade materials such as stainless steel
The Siemens 7MF4033 1EA00+ SITRANS P DS III Pressure Transmitter is a user friendly and highly accurate digital transmitter. The 7MF4033 Pressure Transmitteris simple to use, but comes with a wide range of options. This extensive functionality allows the 7MF4033 to be precisely adapted to your requirements.
7MF4033 Pressure Transmitter Benefits
High quality and long service life
Reliability under extreme chemical and mechanical loads
Suitable for both aggressive and non-aggresive gasses, vapors and liquids
Extensive diagnosis and simulation functions
Wetted parts made from high grade materials such as stainless steel
DS III / P410, HART,4-20 mA
Span: 8.3-250 mbarg Overload limit 6 bar
Diaphragm & Cell stainless steel
Process connection: G1/2
Die-cast aluminium housing
no Explosion protection
Electric connection -Cable gland M20 x 1.5
With digital display hidden
DS III / P410, HART,4-20 mA
Span: 0,83 ... 250 Mbarg Overload limit 6 bar
Diaphragm & Cell stainless steel
Process connection: G1/2
Die-cast aluminium housing
Explosion protection EEx ia + EExd
Electric connection -Cable gland M20 x 1.5
With digital display hidden
SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,01 ... 1 bar g (0.15 ... 14.5 psi g), overload limit 6 bar Diaphragm stainless steel, measuring cell stainless steel Process connection: connection shank G1/2 B to EN 837-1 Die-cast aluminium housing Standard design None explosion protection Electric connection and cable inlet: cable gland M20 x 1.5 Without Indicator Range (linear characteristic) specify in plain text:, Y01 -140 to + 560mBar Y01:-140mbar - + 560mbar
SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Measuring cell filling silicone oil, normal cleaning Span: 0,01 ... 1 bar g (0.15 ... 14.5 psi g), overload limit 6 bar Diaphragm stainless steel, measuring cell stainless steel Process connection: connection shank G1/2 B to EN 837-1 Die-cast aluminium housing Standard design None explosion protection Electric connection and cable inlet: cable gland M20 x 1.5 Without Indicator Range (linear characteristic) specify in plain text:, Y01 -140 to + 560mBar Y01:-140mbar - + 560mbar
DS III / P410, HART,4-20 mA
Span: 0,01 -1 barg Overload limit 6 bar
Diaphragm & Cell stainless steel
Process connection: G1/2
Die-cast aluminium housing
No Explosion protection
Electric connection -Cable gland M20 x 1.5
Visible digital display
SITRANS P DS III / P410, HART,4-20 mA Transmitter for pressure 7MF4033 1 Measuring cell filling silicone oil, normal cleaning B Span: 0,01 ... 1 bar g overload limit 6 bar A Diaphragm stainless steel, measuring cell stainless steel 0 Process connection: connection shank G1/2 B to EN 837-1 0 Die-cast aluminium housing 1 Standard design B Explosion protection EEx ia B Electric connection and cable inlet: cable gland M20 x 1.5 6 Housing cover with window Y01 Range (linear characteristic) -100 to + 400 mbar C11 Quality inspection certificate (Factory calibration) to IEC 60770-2 Full P/N 7MF40331BA001BB6.Z.Y01 C11
SITRANS P DS III / P410, HART,4-20 mA Transmitter for pressure 7MF4033 1 Measuring cell filling silicone oil, normal cleaning B Span: 0,01 ... 1 bar g overload limit 6 bar A Diaphragm stainless steel, measuring cell stainless steel 0 Process connection: connection shank G1/2 B to EN 837-1 0 Die-cast aluminium housing 1 Standard design B Explosion protection EEx ia B Electric connection and cable inlet: cable gland M20 x 1.5 6 Housing cover with window Y01 Range (linear characteristic) -100 to + 400 mbar C11 Quality inspection certificate (Factory calibration) to IEC 60770-2 Full P/N 7MF40331BA001BB6.Z.Y01 C11
DS III / P410, HART,4-20 mA
Span: 0,01 ... 1 barg Overload limit 6 bar
Diaphragm & Cell stainless steel
Process connection: G1/2
Die-cast aluminium housing
Explosion protection EEx ia
Electric connection -Cable gland M20 x 1.5
Visible digital display
DS III / P410, HART,4-20 mA
Span: 0.1-1 barg Overload limit 6 bar
Diaphragm & Cell stainless steel
Process connection: G1/2
Die-cast aluminium housing
No Explosion protection
Electric connection -Cable gland M20 x 1.5
With digital display hidden
DS III / P410, HART,4-20 mA
Span: 0,01 ... 1 barg Overload limit 6 bar
Diaphragm & Cell stainless steel
Process connection: G1/2
Die-cast aluminium housing
Explosion protection EEx ia + EExd
Electric connection -Cable gland M20 x 1.5
With digital display hidden
SITRANS P DS III / P410, HART,4-20 mA
Transmitter for pressure
7MF4033-
1 Measuring cell filling silicone oil,
normal cleaning
B Span: 0,01 ... 1 bar g (0.15 ... 14.5
psi g), overload limit 6 bar
A Diaphragm stainless steel, measuring
cell stainless steel
6 Process connection: Male thread
1/2-14NPT
0 Die-cast aluminium housing
1 Standard design
B Explosion protection EEx ia
B Electric connection and cable inlet:
cable gland M20 x 1.5
6 Housing cover with window
SITRANS P DS III / P410, HART,4-20 mA
Transmitter for pressure
7MF4033-
1 Measuring cell filling silicone oil,
normal cleaning
B Span: 0,01 ... 1 bar g (0.15 ... 14.5
psi g), overload limit 6 bar
A Diaphragm stainless steel, measuring
cell stainless steel
6 Process connection: Male thread
1/2-14NPT
0 Die-cast aluminium housing
1 Standard design
B Explosion protection EEx ia
B Electric connection and cable inlet:
cable gland M20 x 1.5
6 Housing cover with window
7MF4033- 1 Measuring cell filling silicone oil, normal cleaning C Span: 0,04 ... 4 bar g (0.58 ... 58 psig overload limit 10 bar A Diaphragm stainless steel, measuring cell stainless steel 0 Process connection: connection shank G1/2 B to EN 837-1 0 Die-cast aluminium housing 1 Standard design A None explosion protection A Electric connection and cable inlet: screwed gland PG 13.5 6 Housing cover with window SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Netweight: 2.000 KG Commodity code.: 90262020
7MF4033- 1 Measuring cell filling silicone oil, normal cleaning C Span: 0,04 ... 4 bar g (0.58 ... 58 psig overload limit 10 bar A Diaphragm stainless steel, measuring cell stainless steel 0 Process connection: connection shank G1/2 B to EN 837-1 0 Die-cast aluminium housing 1 Standard design A None explosion protection A Electric connection and cable inlet: screwed gland PG 13.5 6 Housing cover with window SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure Netweight: 2.000 KG Commodity code.: 90262020
SITRANS P DS III / P410, HART,4-20 mA Transmitter for pressure 7MF4033 1 Measuring cell filling silicone oil, normal cleaning C Span: 0.004 ... 4bar g overload limit 10 bar A Diaphragm stainless steel, measuring cell stainless steel 0 Process connection: connection shank G1/2 B to EN 837-1 0 Die-cast aluminium housing 1 Standard design B Explosion protection EEx ia B Electric connection and cable inlet: cable gland M20 x 1.5 6 Housing cover with window Y01 Range (linear characteristic) -1 to + 4 bar C11 Quality inspection certificate (Factory calibration) to IEC 60770-2 Full P/N 7MF40331CA001BB6.Z.Y01 C11
SITRANS P DS III / P410, HART,4-20 mA Transmitter for pressure 7MF4033 1 Measuring cell filling silicone oil, normal cleaning C Span: 0.004 ... 4bar g overload limit 10 bar A Diaphragm stainless steel, measuring cell stainless steel 0 Process connection: connection shank G1/2 B to EN 837-1 0 Die-cast aluminium housing 1 Standard design B Explosion protection EEx ia B Electric connection and cable inlet: cable gland M20 x 1.5 6 Housing cover with window Y01 Range (linear characteristic) -1 to + 4 bar C11 Quality inspection certificate (Factory calibration) to IEC 60770-2 Full P/N 7MF40331CA001BB6.Z.Y01 C11
SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure 1 Measuring cell filling silicone oil, normal cleaning C Span: 0,04 ... 4 bar g (0.58 ... 58 psi g), overload limit 10 bar A Diaphragm stainless steel, measuring cell stainless steel 0 Process connection: connection shank G1/2 B to EN 837-1 0 Die-cast aluminium housing 1 Standard design B Explosion protection EEx ia B Electric connection and cable inlet: cable gland M20 x 1.5 7 Housing cover with window (digital indicator visible, Y21 Adjustment digital indicator Range in bar to be confirmed Full P/N 7MF4033-1CA00-1BB7-Y21
SITRANS P DS III / P410, HART,4-20 mA transmitter for pressure 1 Measuring cell filling silicone oil, normal cleaning C Span: 0,04 ... 4 bar g (0.58 ... 58 psi g), overload limit 10 bar A Diaphragm stainless steel, measuring cell stainless steel 0 Process connection: connection shank G1/2 B to EN 837-1 0 Die-cast aluminium housing 1 Standard design B Explosion protection EEx ia B Electric connection and cable inlet: cable gland M20 x 1.5 7 Housing cover with window (digital indicator visible, Y21 Adjustment digital indicator Range in bar to be confirmed Full P/N 7MF4033-1CA00-1BB7-Y21
DS III / P410, HART,4-20 mA
Span: 0,16 ... 16 barg Overload limit 10 bar
Diaphragm & Cell stainless steel
Process connection: G1/2
Die-cast aluminium housing
Explosion protection EEx ia & Eexd ATEX
Electric connection -Cable gland M20 x 1.5
With visible digital display hidden