LANDON KINGSWAY ALARM - AUDIO VISUAL ALARM ALARM

LANDON KINGSWAY ALARM - AUDIO VISUAL ALARM

This is an essential form of alarm where there is a need, for example, hearing and visually impared people, where it can be both seen and heard. The audio visual alarm provides both an electronic sounder and a Xenon beacon unit with a sounder ‘mute’ device.

 

24V DC Version

230 V AC Version

95dB intermittent tone

Contact us about this product

PDF Datasheet
LANDON KINGSWAY CABINET - DRY RISER INLET & OUTLET CABINETS CABINET

LANDON KINGSWAY CABINET - DRY RISER INLET & OUTLET CABINETS

Dry riser gate valves act as outlets from the riser main. These valves are situated on each floor of the high rise building and are normally housed in outlet cabinets which are manufactured to BS5041 part 4. Dry riser gate valves come complete with inlets flanged 65mm BS4504 PN16, 2.5”BS10 table D and screwed 2.5” BSPT, outlets to BS336, complete with blank cap and chain, strap and padlock, complying to BS5041 part 2. An inlet breeching at ground level provides the connection to the water supply. The system is normally dry and is charged by the fire brigade in an emergency. Breeching inlets have either 2 or 4 inlet connections complete with 2.5” male instantaneous inlets to BS336 fitted with non-return valves, 1” drain valve and caps and chains. A 100mm (4”) rising main uses a 2-way inlet breeching in a vertical or horizontal position. A 150mm (6”) rising main uses a 4-Way inlet breeching.

 

Available in:

Dry Riser Outlet Cabinet

Dry Riser Inlet Cabinet

Contact us about this product

PDF Datasheet
LANDON KINGSWAY CABINET - FOAM INLET CABINET CABINET

LANDON KINGSWAY CABINET - FOAM INLET CABINET

These cabinets house the connections which allow fire fighters to pump foam down the foam circuit and onto a fire. They are required when it is known that the local fire brigade use mechanical foam generators. Foam inlet cabinets are designed and manufactured to conform to BS5041.

 

Available in:

Single Point Inlet

Dual Point Inlet

Triple Point Inlet

Contact us about this product

PDF Datasheet
LANDON KINGSWAY CABINET - OIL FILLPOINT CABINETS CABINET

LANDON KINGSWAY CABINET - OIL FILLPOINT CABINETS

Manufactured from Zintec coated steel and finished in powder coat paint for high corrosion resistance. Bespoke cabinets to your design requirements are available to special order. (Please contact us for details)

 

Available in:
A Type Single Point
B Type Double Point
C Type Triple Point
Also available in Stainless Steel

Contact us about this product

PDF Datasheet
LANDON KINGSWAY CHARGER - BATTERY TRICKLE CHARGER TRICKLE CHARGER

LANDON KINGSWAY CHARGER - BATTERY TRICKLE CHARGER

Designed for fire alarm or stand alone use. Battery space is provided in all models. Their solid construction, complimented by a pleasing, textured, grey finish enclosure, ensures they are suitable for a wide range of applications. Designed specifically for sealed lead acid batteries, microprocessor control ensures correct management of the charging voltage and current. Fault monitoring outputs are provided for remote signalling, together with led indications on the enclosure door. Can be used for continuous load applications, such as Smoke Dispersal Systems. Load relays, with changeover contacts, are standard fitment.

 

Designed to EN54 Pt.4
For fire alarm or stand alone use
Solid construction
Proven reliability
Constant voltage charging
Visual and audible fault warnings
Space for batteries
Suitable for sealed lead acid batteries
Supplied with double pole relay outputs for Smoke
Dispersal or Bell Booster use
Fault relay output

Contact us about this product

PDF Datasheet
LANDON KINGSWAY ELECTROMEK MKII - QUICK RELEASE MECHANISM MKII

LANDON KINGSWAY ELECTROMEK MKII - QUICK RELEASE MECHANISM

The Electromek is a manual quick release mechanism that also contains a pair of change-over contacts that operate either when the button is pushed or when the cable goes slack for any other reason (such as a thermal link melting). The electrical contacts may be used to sound an alarm, de-activate equipment or send a signal to a fire control panel.

 

Enclosure Diecast Aluminium Alloy
Dimensions 131 x 172 x 102mm overall
Fixing Centres 4 holes, Ø4mm
Protection Rating IP52
Switch Rating 250V AC, 5A
Wire Size 2.5mm² max
Conduit Connection 2x 20mm E.T.
Pressure to release 40N approx.
Min plunger loading 23N minimum
Weight 1.4kg

Contact us about this product

PDF Datasheet
LANDON KINGSWAY FLOAT UNIT - FILGUARD FLOAT UNITS FLOAT UNIT

LANDON KINGSWAY FLOAT UNIT - FILGUARD FLOAT UNITS

Float units are available in standard form. Each unit is of robust construction, the stainless steel float being compatible with most oil based liquids including corn oil. Floats in different materials can be provided on request.

 

• Materials: Stainless Steel float, Grey painted cast iron housing

• Protection rating: IP65

• Mounting Connection: 3” BSP

• Liquid Switch-point: 100mm above base of float

• Contact Rating: 10A max.

Contact us about this product

PDF Datasheet
LANDON KINGSWAY GAUGE - HYDROSTATIC CONTENTS GAUGE GAUGE

LANDON KINGSWAY GAUGE - HYDROSTATIC CONTENTS GAUGE

The gauge system requires no external power source. Indication of tank contents can be in any units of mass, volume or depth. Tank sensors are available in mild steel, stainless steel, brass, aluminium and also a range of plastics including PVC. Each system is tailor made to each user’s requirements, with data being prepared from the individual tank questionnaire. Depending on tank depth, the capillary may be up to 100 metres long without degrading the accuracy of the instrument. The sensor is available with a sealed capillary to remote indicators or for more difficult installations with detachable capillary.

 

• Gauge diameters 100, 160 & 250mm

• Gauge material Stainless Steel

• Connection ¾” BSP c/w isolating valve

Contact us about this product

PDF Datasheet
LANDON KINGSWAY GMDX - MULTI JET WATER METER GMDX

LANDON KINGSWAY GMDX - MULTI JET WATER METER

The GMDX multi jet water meter is suitable for general purpose and commercial metering applications, supplied with nuts, tails and washers. For use on vertical or horizontal applications.

 

• 1/2” – 2” Diameter

• PN16

• Flow Rate: 3-30 m3/hr

• Max pressure: 16 Bar

• For use on: Cold water (+30°C)

• Class B-H

Contact us about this product

PDF Datasheet
LANDON KINGSWAY GSD - SINGLE JET WATER METER GSD

LANDON KINGSWAY GSD - SINGLE JET WATER METER

The GSD single jet water meter is a compact design for most metering applications, supplied with nuts, tails and washers. Suitable for vertical or horizontal installation.

 

• 1/2” – 3/4” Diameter

• PN16

• Flow Rate: 3-5 m3/hr

• Max pressure: 16 Bar

• For use on: Cold water (+30°C) and Warm water (+90°C)

• Class B-H/A-V