8010 |
BURKERT TYPE 8010 - MAGNETIC PADDLE (FLIPPER) FLOW SWITCH
The 8010 is a magnetic paddle flow switch for on/off control. Available with normally open or closed, relays this unit can be fitted to a choice of body materials and sizes.
• On/Off Control • Relay Output • Easy Setup
Contact us about this product
|
PDF Datasheet
PDF Manual
|
 |
8030 |
BURKERT TYPE 8030 - FLOW SENSOR
The paddle-wheel flow sensor is specially designed for use in neutral, solid-free liquids. The sensor is made of a compact fitting with integrated paddle-wheel and an electronic-nodule, quickly and easily connected together by a bayonet. The hall-sensor produces a frequency signal proportional to the flow which can easily be transmitted and process.
• Pipe diameter DN 15...50 • Measuring range 0.3...10m/s • Measuring error • Output signal Transistor PNP and NPN • Supply voltage 12...30 VDC • Enclosure IP 65 • Fluid temperature maximum 0°C … +100°C
Contact us about this product
|
PDF Datasheet
PDF Manual
|
 |
8032 |
BURKERT TYPE 8032 - FLOW SENSOR/SWITCH
This paddle wheel Flow Sensor/Switch is specially designed to establish an ON/OFF Control loop. The switching point can be programmed with the 3 key pads on the display or can optionally be programmed externally from a programmable logic controller over a 4...20 mA loop.
• Pipe diameter DN 15...DN 50 • Measuring range 0.2m/s...10m/s • Switching accuracy +/-1% • Repeatability 0.4% o.R. • Voltage supply 12...30 VDC • Fluid temperature max. 100°C
Contact us about this product
|
PDF Datasheet
PDF Manual
|
 |
8025 |
BURKERT TYPE 8025 - DIGITAL FLOW TRANSMITTER
The paddle-wheel flow transmitter for continuous flow measurement and batch control is specially designed for use in neutral and slightly aggressive, solid-free liquids. The transmitter 8025 is a compact unit with integrated sensor or a remote mounted sensor 8020 with panel or wall mounted transmitter. The transmitter produces 4...20mA standard signal proportional to the flow and provides a freely adjustable pulse output.
• 4...20mA standard output signal • Pulse output (NPN, PNP or reed) • Local flow display • 2 totalizers display • 2 programmable thresholds
Contact us about this product
|
PDF Datasheet
PDF Manual
|
 |
8035 |
BURKERT TYPE 8035 - BATCH CONTROLLER
The paddle-wheel flow transmitter and batch controller is quickly and easily connected together by a bayonet. The transmitter component converts the measured signal and displays the actual value. Display and menu-guided operating elements allow a customised adjustment of all measuring parameters.
• Pipe diameter DN 15 … 50 • Measuring range 0.3 … 10 m/s • Measuring error +/-0.5% • Fluid temperature maximum 0°C … +100°C • Fitting Brass, ST/ST or Plastic • Voltage supply 12 .. 30 VDC or 90-240 VAC • Output signal 4...20 mA • Relay output 2, freely programmable
Contact us about this product
|
PDF Datasheet
PDF Manual
|
 |
8024 |
BURKERT TYPE 8024 - EASY FLOW INDICATOR
The 8024 paddle wheel flow indicator is used for continuous flow measurement. Available with a choice of display ranges and engineering units making this unit an excellent option to a VA meter.
• Local or remote display • Choice of body • Large display • Alternative to VA meters
Contact us about this product
|
PDF Datasheet
PDF Manual
|
 |
8035 |
BURKERT TYPE 8035 - INLINE FLOW TRANSMITTER
Type 8035 INLINE Flow Transmitter/Dosing Unit consists of a compact body with an integrated paddle wheel (S030) and an electronics module. Boasting an 8 to 50mm orifice range, this unit is ideal for flow measurement of liquids with low solid content. It is available as either a compact version for control cabinet or field monitoring.
• Paddle wheel technology (DN6 to DN65) • Flow indication including 2 totalisers with optional alarm relays • 4...20mA and calibrated pulse output • Available as compact version with options for remote mounting
Contact us about this product
|
PDF Datasheet
PDF Manual
|
 |
S020 |
BURKERT TYPE S020 - INSERTION FITTING FOR FLOW MEASUREMENT
The fitting can be used to connect any INSERTION device for a measurement in the pipe. i.e. sensors, indicators, transmitters and controllers for flow, pH, ORP and conductivity measurement. Suitable for use on Type 8025.
• Port Connection: G 1/2 - G 2 (NPT & Rc Available on request)
• Body Material: Brass (CuZn39Pb2) & stainless steel (316L -1.4435), all in stainless steel (316L -1.4435) or all in PVC, PP, PVDF, PE
• Seal Material: FKM or EPDM
• Fluid Pressure: PN10, PN16
Contact us about this product
|
PDF Datasheet
PDF Manual
|
 |
S030 |
BURKERT TYPE S030 - INSERTION FITTING FOR FLOW MEASUREMENT
The fitting S030 has a built-in paddlewheel to measure the flow rate. When liquid flows through the pipe, the paddle-wheel is set in rotation producing pulses which frequency is proportional to the flow rate. This leads to a very leak-proof construction, called the ”INLINE Quarterturn” technology. The paddle-wheel rotation is detected contactless through the fitting wall. The sensor unit can be snapped-on or removed without opening the pipe or interrupting the process. Suitable for use on Type 8030, Type 8032 and Type 8035.
• Port Connection: G 1/2 - G 2 (NPT & Rc Available on request)
• Body Material: Stainless steel (316L -1.4435), brass, PVC, PP, PVDF
• Seal Material: FKM or EPDM
• Fluid Pressure: PN10, PN16
Contact us about this product
|
PDF Datasheet
PDF Manual
|