Looking for a specific part?
Flow Meters
Inline MFM for nominal flow rates from 25 lN/min to 1,500. lN/min; 1/4' to 3/4'. High accuracy. Fast response time. Fieldbus option.
Accuracy 0.3% OFS (0.1% Repeatability), Neutral gas applications, Max Pressure 10bar, Max Flow up to 1500l/min.
Flowmeter for gases and installation in existing pipes, depth scale for accurate installation, from 1/2" up to 12" (DN300), up to 44030 Nm3/h, 4-20 mA output signal
Flowmeter for gases, integrated inlet and outlet pipes, up to 2", up to 825 Nm3/h, 4-20 mA output signal
On/Off Control, Relay Output, Easy Setup.
4-20mA standard output signal, Pulse output (NPN, PNP or reed), Local flow display, 2 totalizers display, 2 programmable thresholds.
Pipe diameter DN 15-50, Measuring range 0.3-10m/s, Measuring error, Output signal Transistor PNP and NPN, Supply voltage 12-30 VDC, Enclosure IP 65, Fluid temperature maximum 0°C to +100°C.
Pipe diameter DN 15-DN 50, Measuring range 0.2m/s-10m/s, Switching accuracy +/-1%, Repeatability 0.4% o.R. Voltage supply 12-30 VDC, Fluid temperature max. 100°C.
Pipe diameter DN 15- 50, Measuring range 0.3 - 10 m/s, Measuring error +/-0.5%, Fluid temperature maximum 0C +100°C.
Paddle wheel technology (DN6 to DN65), Flow indication including 2 totalisers with optional alarm relays, 4-20mA and calibrated pulse output, Available as compact version with options for remote mounting.
Working as a transmitter and/or as an ON/OFF controller, Automatic calibration of full scale: TEACH-IN, Clean in place (CIP), FDA approved.
Measuring range 0.05 - 10 m/s, Repeatability =/-0.25% o.R. Display 8-digit LC-display, Fluid conductivity > 20 uS, Fluid temperature maximum 0 to 80°C, Sensor material Body in PVDF electrodes Stainless Steel.
DN 3 up to DN 100, Measuring range 0-10 l/h, 0-280 m3/h, Accuracy +/- 0.2%. Process connection DIN 11851, Tri-Clamp, Threaded ISO 228-1 and NPT, Flanged DIN 2501, ANSI 150 RF. Body materials: Stainless steel, Carbon Steel. Lining PTFE or PP
Pipe diameter DN 3- 100, Measuring range 00…10 l/h to 0…28 m3/h Measuring error +/-0.2%, Fluid temperature maximum 0C +100°
High accuracy. Medium with high viscosity. Mounting and dismounting of the sensor head by a quarter-turn. Connection to Burkert devices in remote versions.
For highly viscous fluids. Electronics for indication, monitoring, transmitting, On/Off. control and batch control.
Indication, monitoring, transmitting and On/Off control in one device. Programmable outputs (transistor or relay). Automatic-calibration: Teach-In. Communication - external setpoints and process value (4-20 mA).
Brass with Silicone Seals PPS, Sizes - DN15 - DN25, Connection - BSP or NPT External thread 3/4', 1' or 1 1/4'.
Pipe diameter DN 0.8- 80, Measuring range 0.3 - 10 m/s, Measuring error 10% of full scale up to full scale: ±0.4% of the measured value Fluid temperature maximum 0C +100°C.
THIS PRODUCT IS NO LONGER AVAILABLE Pressure Range: 0.30 up to 10 metres, Accuracy: +/ 0.25% of full scale, Resolution: +/- 3mm, Supply Voltage: 18-32 VDC or 110-230AC, Medium temperature: -40 up to +80°C.
Bypass MFM with capillary technology for nominal flow rates from 5 mlN/min to 10 lN/min. Applicable for aggressive gases. Fieldbus option.
Accuracy 0.3% OFS (0.1%Repeatability), Neutral gas applications, Max Pressure 10bar, PROFIBUS DP & DeviceNet communication.
High dynamic flow measurement. Applicable for liquid flow measurement up to 600 ml/min (36 l/h). No moving parts in medium. Fieldbus optional. Compact version.
Accuracy 0.3% OFS (0.1% Repeatability), Liquids, Max Pressure 10bar, Max Flow 600mL/min.
High dynamic flow measurement. Applicable for liquid flow measurement up to 600 ml/min (36 l/h). No moving parts in medium. Fieldbus optional.
Accuracy 0.3% OFS (0.1% Repeatability), Aggressive & Toxic Gases, Max Pressure 10bar, Max Flow 10L/min.
High dynamic control through fast flow measurement. Applicable for liquid dosing up to 600 ml/min (36 l/h). No moving parts in medium. Fieldbus optional.
The flow rate controller, Type 8750, is a system to measure and control gases using the differential pressure principle. The reliable and robust system consists of an ELEMENT continuous control valve, Type 2301, with the compact process controller Type 8693 and two pressure transmitters, Type 8323.
Port Connection: G 1/2 - G 2 (NPT & Rc Available on request) Body Material: Brass (CuZn39Pb2) & stainless steel (316L -1.4435), all in stainless steel (316L -1.4435) or all in PVC, PP, PVDF, PE Seal Material: FKM or EPDM Fluid Pressure: PN10, PN16
Port Connection: G 1/2 - G 2 (NPT & Rc Available on request) Body Material: Stainless steel (316L -1.4435), brass, PVC, PP, PVDF Seal Material: FKM or EPDM Fluid Pressure: PN10, PN16
Our brands include Burkert and Siemens, and with cast iron, brass, stainless steel and plastic bodies to choose from, and a wide selection of seal materials, there's sure to be a flow meter to meet the tough demands of every eventuality.
All our flow meters are available with downloadable manuals and technical data sheets, but if you have any special flow measurement challenges you'd like to discuss, our fully trained engineers are always on hand. Simply drop us a message online, or call our experts on +44 (0) 800 328 8511.