Industrial Landscape
SERVICES PRODUCTS MORE INFO
IMAGE MODEL DESCRIPTION RESOURCES
BURKERT TYPE 8006 - MFM MASS FLOW METER FOR GASES 8006

BURKERT TYPE 8006 - MFM MASS FLOW METER FOR GASES

Mass flow meters are used in process technology for the direct measurement of the mass flow of gases. In case of volumetric flow meters, it is necessary to measure the temperature and the pressure either the density, because gases change their density or rather their volume depending on the pressure. The measurement of the mass flow, on the other hand, is independent of the pressure and the temperature. The digital mass flow meter Type 8006 uses an inline sensor based on the thermal principle located directly in the main channel. Due to the fact that the sensor is directly in the main channel a very fast response time of the MFM is reached. Another benefit of this main stream measurement is that it is less sensitive to contamination. The actual flow is given as an analog output signal or could be read out over fieldbus communication. Type 8006 can optionally be calibrated for two different gases, the user is able to switch between these two gases. The materials of the parts that come into contact with the medium are selected according to customer specification so that the unit can be operated with the complete range of standard process gases.

 

• Inline MFM for nominal flow rates from 25 lN/min to 1,500 lN/min; 1/4” to 3/4”

• High accuracy

• Fast response time

• Fieldbus option

Contact us about this product

PDF Datasheet PDF Manual
BURKERT TYPE 8006/8626 - MASS FLOW METER 8006 8626

BURKERT TYPE 8006/8626 - MASS FLOW METER

The type 8006/8626 mass flow meters and controllers use an inline sensor based on the thermal principle located directly in the main channel of the flow. This provides a very fast response time is reached. Another benefit of this main stream measurement is that it is less sensitive to contamination.


• Accuracy 0.3% OFS (0.1% Repeatability)
• Neutral gas applications
• Max Pressure 10bar
• Max Flow up to 1500l/min

Contact us about this product

PDF Datasheet PDF Manual
BURKERT TYPE 8010 - MAGNETIC PADDLE (FLIPPER) FLOW SWITCH 8010

BURKERT TYPE 8010 - MAGNETIC PADDLE (FLIPPER) FLOW SWITCH

The 8010 is a magnetic paddle flow switch for on/off control. Available with normally open or closed, relays this unit can be fitted to a choice of body materials and sizes.

• On/Off Control
• Relay Output
• Easy Setup 

Contact us about this product

PDF Datasheet PDF Manual
BURKERT TYPE 8025 - DIGITAL FLOW TRANSMITTER 8025

BURKERT TYPE 8025 - DIGITAL FLOW TRANSMITTER

The paddle-wheel flow transmitter for continuous flow measurement and batch control is specially designed for use in neutral and slightly aggressive, solid-free liquids. The transmitter 8025 is a compact unit with integrated sensor or a remote mounted sensor 8020 with panel or wall mounted transmitter. The transmitter produces 4...20mA standard signal proportional to the flow and provides a freely adjustable pulse output.

• 4...20mA standard output signal
• Pulse output (NPN,
PNP or reed)
• Local flow display
• 2 totalizers display
• 2 programmable thresholds 

Contact us about this product

PDF Datasheet PDF Manual
BURKERT TYPE 8030 - FLOW SENSOR 8030

BURKERT TYPE 8030 - FLOW SENSOR

The paddle-wheel flow sensor is specially designed for use in neutral, solid-free liquids. The sensor is made of a compact fitting with integrated paddle-wheel and an electronic-nodule, quickly and easily connected together by a bayonet. The hall-sensor produces a frequency signal proportional to the flow which can easily be transmitted and process.

• Pipe diameter DN 15...50
• Measuring range 0.3...10m/s
• Measuring error
• Output signal Transistor
PNP and NPN
• Supply voltage 12...30 VDC
• Enclosure IP 65
• Fluid temperature maximum 0°C … +100°C 

Contact us about this product

PDF Datasheet PDF Manual
BURKERT TYPE 8032 - FLOW SENSOR/SWITCH 8032

BURKERT TYPE 8032 - FLOW SENSOR/SWITCH

This paddle wheel Flow Sensor/Switch is specially designed to establish an ON/OFF Control loop. The switching point can be programmed with the 3 key pads on the display or can optionally be programmed externally from a programmable logic controller over a 4...20 mA loop.

• Pipe diameter DN 15...DN 50
• Measuring range 0.2m/s...10m/s
• Switching accuracy +/-1%
• Repeatability 0.4% o.R.
• Voltage supply 12...30 VDC
• Fluid temperature max. 100°C

Contact us about this product

PDF Datasheet PDF Manual
BURKERT TYPE 8035 - BATCH CONTROLLER 8035

BURKERT TYPE 8035 - BATCH CONTROLLER

The paddle-wheel flow transmitter and batch controller is quickly and easily connected together by a bayonet. The transmitter component converts the measured signal and displays the actual value. Display and menu-guided operating elements allow a customised adjustment of all measuring parameters.

• Pipe diameter DN 15 … 50
• Measuring range 0.3 … 10 m/s
• Measuring error +/-0.5%
• Fluid temperature maximum 0°C … +100°C
• Fitting Brass, ST/ST or Plastic
• Voltage supply 12 .. 30 VDC or 90-240 VAC
• Output signal 4...20 mA
• Relay output 2, freely programmable 

Contact us about this product

PDF Datasheet PDF Manual
BURKERT TYPE 8035 - INLINE FLOW TRANSMITTER 8035

BURKERT TYPE 8035 - INLINE FLOW TRANSMITTER

Type 8035 INLINE Flow Transmitter/Dosing Unit consists of a compact body with an integrated paddle wheel (S030) and an electronics module. Boasting an 8 to 50mm orifice range, this unit is ideal for flow measurement of liquids with low solid content. It is available as either a compact version for control cabinet or field monitoring.

• Paddle wheel technology (DN6 to DN65)
• Flow indication including 2 totalisers with optional alarm relays
• 4...20mA and calibrated pulse output
• Available as compact version with options for remote mounting

Contact us about this product

PDF Datasheet PDF Manual
BURKERT TYPE 8041 - INSERTION MAGMETER 8041

BURKERT TYPE 8041 - INSERTION MAGMETER

The flow meter 8041 has been designed for pipes with diameters ranging from DN 6 to DN 400 and liquids having a conductivity > 20 μS/cm. The transmitter is a magmeter made up of an electronic module and a stainless steel sensor. It is fitted with a 4-20 mA output, a pulse rate PLC output and a relay output.

 

 Working as a transmitter and/or as an ON/OFF controller

 Automatic calibration of full scale: TEACH-IN

 Clean in place (CIP)

FDA approved

Contact us about this product

PDF Datasheet PDF Manual
BURKERT TYPE 8045 - ELECTROMAGNETIC FLOW METER 8045

BURKERT TYPE 8045 - ELECTROMAGNETIC FLOW METER

The 8045 Magmeter is an insertion flow meter for pipe sizes DN15-DN400. Typical applications are liquids having a conductivity > 20 uS. With sensor bodies in Brass, st/st, PVDF, PVC and PP

• Measuring range 0.05 - 10 m/s
• Repeatability =/-0.25% o.R.
• Display 8-digit LC-display
• Fluid conductivity > 20 uS
• Fluid temperature maximum 0 to 80°C
• Sensor material Body in PVDF electrodes Stainless Steel 

Contact us about this product

PDF Datasheet PDF Manual