8702 |
BURKERT TYPE 8702 - MASS FLOW METER (MFM) FOR GASES
Mass flow meters are used in Process Technology for the direct measurement of the mass flow of gases. In case of volumetric flow meters, it is necessary to measure the temperature and the pressure either the density, because gases change their density or rather their volume depending on the pressure. The measurement of the mass flow, on the other hand, is independent of the pressure and the temperature.
• Accuracy 0.3% OFS (0.1%Repeatability) • Neutral gas applications • Max Pressure 10bar • PROFIBUS DP & DeviceNet communication
Contact us about this product
|
PDF Datasheet
PDF Manual
|
 |
8709 8719 |
BURKERT TYPE 8709 & 8719 - LIQUID FLOW METER AND FLOW CONTROLLER
The integration of sensor, control electronics and proportional valves into a single compact device enables Burkert’s new Liquid Flow Controller (LFC) to provide fast and accurate measurement and dosage of small volumes of liquids with nominal flow rates of 10 – 600 ml/min (0.6 to 36 l/h) with a 1:10. measuring span.
• Accuracy 0.3% OFS (0.1% Repeatability) • Liquids • Max Pressure 10bar • Max Flow 600mL/min
Contact us about this product
|
PDF Datasheet
PDF Manual
|
 |
8006 8626 |
BURKERT TYPE 8006/8626 - MASS FLOW METER
The type 8006/8626 mass flow meters and controllers use an inline sensor based on the thermal principle located directly in the main channel of the flow. This provides a very fast response time is reached. Another benefit of this main stream measurement is that it is less sensitive to contamination.
• Accuracy 0.3% OFS (0.1% Repeatability) • Neutral gas applications • Max Pressure 10bar • Max Flow up to 1500l/min
Contact us about this product
|
PDF Datasheet
PDF Manual
|
 |
8710 |
BURKERT TYPE 8710 - MASS FLOW CONTROLLER
Burkert’s new 8710 Mass Flow Controller and 8700 Mass Flow Meter integrate the company’s innovative Flow Capillary sensor technology, which is ideal for use with aggressive gases due to its isolation from the gas flow path.
• Accuracy 0.3% OFS (0.1% Repeatability) • Aggressive & Toxic Gases • Max Pressure 10bar • Max Flow 10L/min
Contact us about this product
|
PDF Datasheet
PDF Manual
|
 |
8709 |
BURKERT TYPE 8709 - LFM LIQUID FLOW METER
Type 8709 is an instrument for liquid flow measurement in process technology. The actual value supplied by the sensor is transmitted through the digital electronics and over a standard signal output or a field bus interface. In the device two calibration curves can be stored, which the user is able to switch between.
• High dynamic flow measurement
• Applicable for liquid flow measurement up to 600 ml/min (36 l/h)
• No moving parts in medium
• Fieldbus optional
Contact us about this product
|
PDF Datasheet
PDF Manual
|
 |
8708 |
BURKERT TYPE 8708 - LFM LIQUID FLOW METER
Type 8708 is an instrument for liquid flow control in process technology. The actual value supplied by the sensor is transmitted through the digital electronics and over a standard signal output or a field bus interface. In the device two calibration curves can be stored, which the user is able to switch between.
• High dynamic flow measurement
• Applicable for liquid flow measurement up to 600 ml/min (36 l/h)
• No moving parts in medium
• Fieldbus optional
• Compact version
Contact us about this product
|
PDF Datasheet
PDF Manual
|
 |
8719 |
BURKERT TYPE 8719 - LFC LIQUID FLOW CONTROLLER
Type 8719 is an instrument for liquid flow control in process technology. The measured value provided by the sensor will be compared in the digital control electronics with the predefined set point according to the signal; if a control difference is present, the control value output to the proportional valve will be modified using a PI-control algorithm. In this way, the flow can be maintained at a fixed value or a predefined profile can be followed, regardless of pressure changes or other disturbances in the system.
• High dynamic control through fast flow measurement
• Applicable for liquid dosing up to 600 ml/min (36 l/h)
• No moving parts in medium
• Fieldbus optional
Contact us about this product
|
PDF Datasheet
PDF Manual
|
 |
8700 |
BURKERT TYPE 8700 - MFM MASS FLOW METER FOR GASES
Mass flow meters are used in process technology for the direct measurement of the mass flow of gases. In case of volumetric flow meters, it is necessary to measure the temperature and the pressure either the density, because gases change their density or rather their volume depending on the pressure. The measurement of the mass flow, on the other hand, is independent of the pressure and the temperature.
• Bypass MFM with capillary technology for nominal flow rates from 5 mlN/min to 10 lN/min
• Applicable for aggressive gases
• Fieldbus option
Contact us about this product
|
PDF Datasheet
PDF Manual
|
 |
8006 |
BURKERT TYPE 8006 - MFM MASS FLOW METER FOR GASES
Mass flow meters are used in process technology for the direct measurement of the mass flow of gases. In case of volumetric flow meters, it is necessary to measure the temperature and the pressure either the density, because gases change their density or rather their volume depending on the pressure. The measurement of the mass flow, on the other hand, is independent of the pressure and the temperature. The digital mass flow meter Type 8006 uses an inline sensor based on the thermal principle located directly in the main channel. Due to the fact that the sensor is directly in the main channel a very fast response time of the MFM is reached. Another benefit of this main stream measurement is that it is less sensitive to contamination. The actual flow is given as an analog output signal or could be read out over fieldbus communication. Type 8006 can optionally be calibrated for two different gases, the user is able to switch between these two gases. The materials of the parts that come into contact with the medium are selected according to customer specification so that the unit can be operated with the complete range of standard process gases.
• Inline MFM for nominal flow rates from 25 lN/min to 1,500 lN/min; 1/4” to 3/4”
• High accuracy
• Fast response time
• Fieldbus option
Contact us about this product
|
PDF Datasheet
PDF Manual
|